We seem to keep seeing videos of US firefighters ventilating before they have fire control and either having a near miss, getting injured or dying.

  • Bluetreefrog@lemmy.worldOPM
    link
    fedilink
    English
    arrow-up
    1
    ·
    1 year ago

    Thanks for the reference.

    I think your snippet proves my point. Once the fire is out, then the urgency is gone. Rather than cause more damage, why not open the doors and windows and bring out the PPV? It also lessens the risk from introducing air if there’s hidden extension.

    • Vector610@lemmy.world
      link
      fedilink
      English
      arrow-up
      1
      ·
      edit-2
      1 year ago

      Well again, it doesn’t say “once the fire is out” It says “once water is applied”. The goal is to make the environment more tenable as quickly as possible. We’re not as concerned with damage to the property at this point. The main focus is still making things easier for the interior teams by removing heat, smoke, and heated gases. And potentially increase the odds for any survivors. Once we’ve made the environment safe for firefighters, searched for victims, and put the fire out, then we switch to preserving property.

      We don’t want to open doors at this point. Rooms within a structure should be closed/isolated. We want heat/smoke/gases to be removed directly from the structure, not fed further into the structure. But yes, opening windows is a valid form of ventilation, we don’t always need to break things. Once the fire is out, interior doors and fans absolutely help.

      Ventilation shouldn’t be random, it should be coordinated with the interior attack team(s) so that it occurs closest to where they are working. Yes, improper ventilation can feed a fire and alter its flow path, I don’t think anyone would argue that.