Feel free to roast me if this is idiotic. Thank you!

  • Pogbom@lemmy.worldOP
    link
    fedilink
    English
    arrow-up
    3
    ·
    1 year ago

    Damn, this makes a lot of sense. Is there any kind of conduit you would recommend then? I think I’ve seen that anything PVC is ideal for outdoor cables. Would that also help with the condensation risks?

    • Huxleywaswrite@lemmy.world
      link
      fedilink
      English
      arrow-up
      3
      arrow-down
      1
      ·
      1 year ago

      No, pvc is not water tight at all. I’d grab some sealtight flexible conduit, nonmetallic would be fine. Just grab some one hole straps and support the conduit every 6-8 feet. It’s under your deck and you’re a homeowner, not a professional; theres no reason to try and make it straight or neat.

      You will need some sort of an enclosure to run the sealtight to. Any outdoor rated junction box should be fine, mount it as close as you can because your going to be using that ethernet watertight protector to go from the junction box to the camera itself. I’d probably just mount the camera to the enclosure cover itself and make it easy.

      • Pogbom@lemmy.worldOP
        link
        fedilink
        English
        arrow-up
        2
        ·
        1 year ago

        My god I have so much to learn. That makes a lot of sense. Thanks so much for all your help. I’ll get cracking on this in the coming days you might get a few DMs in the near future haha.

          • Pogbom@lemmy.worldOP
            link
            fedilink
            English
            arrow-up
            2
            ·
            edit-2
            1 year ago

            I was gonna DM you but I figured I might as well keep it here in case it can help someone else :)

            It looks like the first few inches of cable coming out of the camera (the segment with the power/ethernet splitter) is outdoor rated. It’s just the thin extension cable and power block cable that are meant for indoors it seems.

            So what if I bought something like this?

            Being sure that it’s compatible, I could run this outdoor rated cable all the way to a junction box right beside the outlet, instead of installing conduit the whole way. Is that a crazy idea?

            • Huxleywaswrite@lemmy.world
              link
              fedilink
              English
              arrow-up
              1
              ·
              1 year ago